Quick View
{"id":4479050547258,"title":"Proximity Switch Assembly TLS2FNB-9-AP","handle":"proximity-switch-assembly-tls2fnb-9-at","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis proximity switch assembly TLS2FNB-9-AP is a PNP equivalent, Normally Open, and sourcing type switch, which replaces TL-S2FN-B-9 on some machines with Fanuc 11T and newer controls.\u003c\/p\u003e\n\u003cp\u003eIn case you could not get the correct result described above, please disconnect the load at terminal-b and re-test. If you can get the correct result without load, it means that the switch is good and troubleshooting by a service professional on the receiver circuit may be needed. \u003c\/p\u003e\n\u003cp\u003eIf you have any additional questions or concerns, please contact the seller at info@\u003ca href=\"mailto:info@accmotion.com\"\u003eaccmotion.com\u003c\/a\u003e, or +1 951 808 7158. We accept returns, if you are not satisfied.\u003c\/p\u003e\n\u003ch5\u003eConnection Diagram\u003c\/h5\u003e\n\u003cp\u003eA simplified connection and mounting diagram is:\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0005\/3418\/3994\/files\/98_ea0f229a-de43-4d2a-948c-be40f05d7148_480x480.jpg?v=1630530730\" alt=\"\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0005\/3418\/3994\/files\/98_ea0f229a-de43-4d2a-948c-be40f05d7148_480x480.jpg?v=1630530730\"\u003e\u003c\/p\u003e\n\u003cp\u003eFor connection as a replacement, see the table below:\u003c\/p\u003e\n\u003ctable style=\"width: 494px;\" height=\"108\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003e\u003cstrong\u003eSignals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003e\u003cstrong\u003eNew switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003e\u003cstrong\u003eOld switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003e12--24V DC\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003eBrown\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003eBlack\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003e0V\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003eBlue\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eTesting\u003c\/h5\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUse a ferrous object to trigger the switch after it is connected and powered on; and then measure the output voltage, Vo, as shown. You should get the following result:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWhen it is not being triggered, its LED should be off and Vo has no voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e If needed, you may connect a 2K resistor between terminal b and c.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWhen it is being triggered, its LED should be on and Vo is about 12—24V DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e In case you could not get the correct result described above, please disconnect the load and test again. If you can get the correct result without load, the conclusion is that the switch is good and the receiving circuit of your control system is fault.\u003c\/p\u003e","published_at":"2020-06-02T14:40:36-07:00","created_at":"2020-06-03T08:26:09-07:00","vendor":"ACC Motion Solutions","type":"Miscellaneous","tags":["Miscellaneous"],"price":11900,"price_min":11900,"price_max":11900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":31670853566522,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"TLS2FNB-9-AP","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Proximity Switch Assembly TLS2FNB-9-AP","public_title":null,"options":["Default Title"],"price":11900,"weight":454,"compare_at_price":null,"inventory_management":"shopify","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/s-l1600_eaf8949a-0fda-4223-ae06-b813504ae1ed.jpg?v=1591197971"],"featured_image":"\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/s-l1600_eaf8949a-0fda-4223-ae06-b813504ae1ed.jpg?v=1591197971","options":["Title"],"media":[{"alt":null,"id":6130813960250,"position":1,"preview_image":{"aspect_ratio":1.514,"height":869,"width":1316,"src":"\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/s-l1600_eaf8949a-0fda-4223-ae06-b813504ae1ed.jpg?v=1591197971"},"aspect_ratio":1.514,"height":869,"media_type":"image","src":"\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/s-l1600_eaf8949a-0fda-4223-ae06-b813504ae1ed.jpg?v=1591197971","width":1316}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThis proximity switch assembly TLS2FNB-9-AP is a PNP equivalent, Normally Open, and sourcing type switch, which replaces TL-S2FN-B-9 on some machines with Fanuc 11T and newer controls.\u003c\/p\u003e\n\u003cp\u003eIn case you could not get the correct result described above, please disconnect the load at terminal-b and re-test. If you can get the correct result without load, it means that the switch is good and troubleshooting by a service professional on the receiver circuit may be needed. \u003c\/p\u003e\n\u003cp\u003eIf you have any additional questions or concerns, please contact the seller at info@\u003ca href=\"mailto:info@accmotion.com\"\u003eaccmotion.com\u003c\/a\u003e, or +1 951 808 7158. We accept returns, if you are not satisfied.\u003c\/p\u003e\n\u003ch5\u003eConnection Diagram\u003c\/h5\u003e\n\u003cp\u003eA simplified connection and mounting diagram is:\u003c\/p\u003e\n\u003cp\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0005\/3418\/3994\/files\/98_ea0f229a-de43-4d2a-948c-be40f05d7148_480x480.jpg?v=1630530730\" alt=\"\" data-mce-fragment=\"1\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0005\/3418\/3994\/files\/98_ea0f229a-de43-4d2a-948c-be40f05d7148_480x480.jpg?v=1630530730\"\u003e\u003c\/p\u003e\n\u003cp\u003eFor connection as a replacement, see the table below:\u003c\/p\u003e\n\u003ctable style=\"width: 494px;\" height=\"108\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003e\u003cstrong\u003eSignals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003e\u003cstrong\u003eNew switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003e\u003cstrong\u003eOld switches\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003e12--24V DC\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003eBrown\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003eBlack\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003eWhite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 145px;\"\u003e0V\u003c\/td\u003e\n\u003ctd style=\"width: 188px;\"\u003eBlue\u003c\/td\u003e\n\u003ctd style=\"width: 139px;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eTesting\u003c\/h5\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUse a ferrous object to trigger the switch after it is connected and powered on; and then measure the output voltage, Vo, as shown. You should get the following result:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWhen it is not being triggered, its LED should be off and Vo has no voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003e If needed, you may connect a 2K resistor between terminal b and c.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eWhen it is being triggered, its LED should be on and Vo is about 12—24V DC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e In case you could not get the correct result described above, please disconnect the load and test again. If you can get the correct result without load, the conclusion is that the switch is good and the receiving circuit of your control system is fault.\u003c\/p\u003e"}