Quick View
{"id":568367415354,"title":"Profibus Remote IO RT133-3FC10-DP","handle":"art133-3fc10-dp","description":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eProfibus DP Remote IO, 8 inputs\/8 outputs, AI*8\/AO*4\u003c\/p\u003e\n\u003cp\u003eSOFTLINK remote I\/O is suitable for linking to a modular system. The RT13X module is able to bring the digital input signals from the field into the Profibus control system via DP net in a long distance. It is dual function of module and slave, maximum flexibility with small size and cost efficiency.\u003c\/p\u003e\n\u003cp\u003eIn order to meet the needs of machine manufacturers and users, distributed automation architecture is used more and more in a variety of occasions, and implementation and functionality comparable to a centralized system. RT13X series IO is a completely new modular input and output device sit made possible through the bus utilization master to manage the design of automation equipment for distribution in the scene of the switch input and output signals and analog input and output signals, connected to the control system through the rich industrial fieldbus the use of IO communication network IO distribution to multiple locations away from the processor, try closer to the sensors and actuators used in distributed control systems flexible and plays a prominent role .\u003c\/p\u003e\n\u003cp\u003eIn the design of modern automation system, the application of industrial fieldbus impact automation. Why is traditional centralized control structure gradually replaced by distributed intelligent devices? Because it is cost-saving and system –optimizing.\u003c\/p\u003e\n\u003cp\u003eRemote I\/O: Design of 2 layers of terminal makes it easier to connect Optimized wiring design in the module makes cabling easier In automation equipment away from the master controller, long distance cable can result in the attenuation and interference of control signal. Such problem can be avoided in the distributed I\/O system. System processor located in master control room I\/Os distributed in each control position RT13x series I\/O exchange data with master controller via industrial field bus.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable id=\"table1\" border=\"1\" cellpadding=\"2\" cellspacing=\"0\" width=\"100%\" style=\"font-size: 14.44444465637207px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e133-3FC10-DP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eType\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eMix signal I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eDigital Number of Input\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eInput Filter\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0.5ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24VDC (-15%\/+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003e\"1\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003e\"0\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003ePort Protect\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eImpact over voltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eDigital Number of Output\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eMosfet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24VDC (-15%\/+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003e\"1\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eOpen drain output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003e\"0\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eMax: 1.5VDC,10kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eMax. Output Current (per Ch.)\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eShort Circuit Current (per Ch.)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eMax. Output Current (Total.)\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eOn-Resistance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.3Ω(type)\/0.6Ω(Max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003ePort Protect\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eOvervoltage \u0026amp; overcurrent protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eAnalog Number of Input\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eSignal Type\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eUnidirectional or bidirectional current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e250kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eSampling Range\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0~5V,0~10V,+\/-1.25V,+\/-2.5V,+\/-5V,+\/- 10V\u003cbr\u003e4~20mA, 0~20mA, +\/-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eSampling Error\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e\u0026lt; +\/- 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026gt; 100kSPS\/ch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eFiltering Software\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eNot adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eAnalog Number of Output\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eOutput Range\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0~10V, 0~20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eOutput Error\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e\u0026lt; +\/- 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eConversion Time\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e~100uS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003ePort Protect\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24VDC (-15%\/+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eElectrical Isolation (Bus\/Field protential)\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eAC 500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eProtocol\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eProfibus DP V0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eBus Connector\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eD-Sub9 Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10kbps~1Mbps Config by 3-bit dial switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eAddress Config\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e00 ~ 99 (Config by 2-bit dial switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eFixed Method\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDIN rail (TS35)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eLED Indicate\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003ePWR:Green;ERR:Red;DE,Data exchange:Orange;Digital I\/O:Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0~+55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e-25~+85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eHumidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e≤85%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eApprovals\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eSize (W\/H\/D,mm)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e155x105x55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eProtect. class\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eLoad\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026gt;5KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2018-03-30T14:19:38-07:00","created_at":"2018-03-30T14:19:38-07:00","vendor":"ACC Motion Solutions","type":"PLC \u0026 I\/O Products \u003e iModule Fieldbus I\/O \u003e Profibus I\/O Module","tags":["Profibus I\/O Module"],"price":56400,"price_min":56400,"price_max":56400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":7179035574330,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"ART133-3FC10-DP","requires_shipping":true,"taxable":false,"featured_image":null,"available":true,"name":"Profibus Remote IO RT133-3FC10-DP","public_title":null,"options":["Default Title"],"price":56400,"weight":907,"compare_at_price":null,"inventory_management":null,"barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/ART133-3FC10-DP-1.jpg?v=1522444778"],"featured_image":"\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/ART133-3FC10-DP-1.jpg?v=1522444778","options":["Title"],"media":[{"alt":null,"id":700917186618,"position":1,"preview_image":{"aspect_ratio":1.399,"height":143,"width":200,"src":"\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/ART133-3FC10-DP-1.jpg?v=1522444778"},"aspect_ratio":1.399,"height":143,"media_type":"image","src":"\/\/acc-motion-solutions.myshopify.com\/cdn\/shop\/products\/ART133-3FC10-DP-1.jpg?v=1522444778","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch5\u003eDescription\u003c\/h5\u003e\n\u003cp\u003eProfibus DP Remote IO, 8 inputs\/8 outputs, AI*8\/AO*4\u003c\/p\u003e\n\u003cp\u003eSOFTLINK remote I\/O is suitable for linking to a modular system. The RT13X module is able to bring the digital input signals from the field into the Profibus control system via DP net in a long distance. It is dual function of module and slave, maximum flexibility with small size and cost efficiency.\u003c\/p\u003e\n\u003cp\u003eIn order to meet the needs of machine manufacturers and users, distributed automation architecture is used more and more in a variety of occasions, and implementation and functionality comparable to a centralized system. RT13X series IO is a completely new modular input and output device sit made possible through the bus utilization master to manage the design of automation equipment for distribution in the scene of the switch input and output signals and analog input and output signals, connected to the control system through the rich industrial fieldbus the use of IO communication network IO distribution to multiple locations away from the processor, try closer to the sensors and actuators used in distributed control systems flexible and plays a prominent role .\u003c\/p\u003e\n\u003cp\u003eIn the design of modern automation system, the application of industrial fieldbus impact automation. Why is traditional centralized control structure gradually replaced by distributed intelligent devices? Because it is cost-saving and system –optimizing.\u003c\/p\u003e\n\u003cp\u003eRemote I\/O: Design of 2 layers of terminal makes it easier to connect Optimized wiring design in the module makes cabling easier In automation equipment away from the master controller, long distance cable can result in the attenuation and interference of control signal. Such problem can be avoided in the distributed I\/O system. System processor located in master control room I\/Os distributed in each control position RT13x series I\/O exchange data with master controller via industrial field bus.\u003c\/p\u003e\n\u003ch5\u003eSpecification\u003c\/h5\u003e\n\u003ctable id=\"table1\" border=\"1\" cellpadding=\"2\" cellspacing=\"0\" width=\"100%\" style=\"font-size: 14.44444465637207px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u003cstrong\u003e133-3FC10-DP\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eType\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eMix signal I\/O module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eDigital Number of Input\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eInput Filter\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0.5ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24VDC (-15%\/+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003e\"1\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003e\"0\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003ePort Protect\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eImpact over voltage protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eDigital Number of Output\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eOutput Type\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eMosfet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24VDC (-15%\/+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003e\"1\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eOpen drain output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003e\"0\" Signal Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eMax: 1.5VDC,10kΩ load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eMax. Output Current (per Ch.)\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eShort Circuit Current (per Ch.)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eMax. Output Current (Total.)\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eOn-Resistance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0.3Ω(type)\/0.6Ω(Max.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003ePort Protect\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eOvervoltage \u0026amp; overcurrent protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eAnalog Number of Input\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eSignal Type\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eUnidirectional or bidirectional current output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eInput impedance\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e250kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eSampling Range\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0~5V,0~10V,+\/-1.25V,+\/-2.5V,+\/-5V,+\/- 10V\u003cbr\u003e4~20mA, 0~20mA, +\/-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16 bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eSampling Error\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e\u0026lt; +\/- 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eSampling Rate\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026gt; 100kSPS\/ch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eFiltering Software\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eNot adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eAnalog Number of Output\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eOutput Range\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e0~10V, 0~20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eResolution\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eOutput Error\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e\u0026lt; +\/- 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eConversion Time\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e~100uS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003ePort Protect\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e24VDC (-15%\/+20%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eElectrical Isolation (Bus\/Field protential)\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eAC 500V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eProtocol\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eProfibus DP V0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eBus Connector\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eD-Sub9 Female\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eCommunication Rate\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e10kbps~1Mbps Config by 3-bit dial switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eAddress Config\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e00 ~ 99 (Config by 2-bit dial switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eFixed Method\u003c\/td\u003e\n\u003ctd align=\"center\"\u003eDIN rail (TS35)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eLED Indicate\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003ePWR:Green;ERR:Red;DE,Data exchange:Orange;Digital I\/O:Green\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e0~+55°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003e-25~+85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eHumidity\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e≤85%RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eApprovals\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eSize (W\/H\/D,mm)\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e155x105x55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\" bgcolor=\"#C9DBE9\"\u003eProtect. class\u003c\/td\u003e\n\u003ctd align=\"center\" bgcolor=\"#C9DBE9\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"center\" width=\"50%\"\u003eLoad\u003c\/td\u003e\n\u003ctd align=\"center\"\u003e\u0026gt;5KΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}